DMIS S I R Entry

Dimensional Measuring Interface Standard
Standard Improvement Request

SIR No.
96-4
DMIS Release
3.0
SIR Type
Enhancement
Severity
Prevents Programming
Status
Resolved
Date Submitted
November 4 1996
Date Validated
November 4 1996
Date In Process

Date Referred

Date Vote Pending

Date Closed
April 30 1997
Action
Clarifications
Submitted By
M.K. Holloway
Lockheed Martin Energy Systems
P.O. Box 2009
Oak ridge TN 37831
USA
Phone: (423)574-6756
Fax: (423)574-2328
hollowaymk@ornl.gov

Problem Topic
DMESW: Wait Period

Problem Description
Cannot specify a period to wait. This is useful for waiting a specified period of time to allowing the part temperature to settle.

References
None

Related SIRs
None

Suggested Resolution
Either create a new major word WAIT (i.e., WAIT/time), or create a new minor word WAIT to be added to the DMESW commands (i.e., DMESW/WAIT,time)

Support Documentation
None


Resolution

Warning!!

The following statement is only a resolution to a Standard Improvement Request (SIR) and is NOT part of the current DMIS standard, nor is it guaranteed to become part of the next revision of the DMIS standard even if voted and accepted by the DMIS National Standards Committee. This resolution is tentative because it may not be incorporated into the next version of the standard, it could be changed prior to the next release, or it could be changed as the result of the "public review and comment" period required for the next version of the standard. If you choose to use this tentative resolution, you do so at your own risk since at this time it is not part of the DMIS standard.

Accepted per 4/97
Create new minor word DELAY and add DELAY option to DMESW's var_1.

Where:

var_1 can be:COMAND,'command'
or:CONTIN
or:DELAY, n
or:PAUSE

DELAYsignifies that the DME is to delay processing data for "n" seconds.
nlength of time in seconds (i.e., DMESW/DELAY,600)

Add DELAY to DMIS 3.0 - TABLE 2.2 DMIS MINOR WORDS table.