DMIS S I R Entry

Dimensional Measuring Interface Standard
Standard Improvement Request

SIR No.
97-32
DMIS Release
3.0
SIR Type
Other
Severity
Interpretation Request
Status
Resolved
Date Submitted
March 6 1997
Date Validated
March 6 1997
Date In Process

Date Referred
April 1 1998
Date Vote Pending

Date Closed
August 20 1998
Action
Clarifications
Submitted By
Dietmar May
Object Workshops, Inc.
PO Box 597
Whytheville VA 24382
USA
Phone: (540)223-1145
Fax: (540)223-1241
dcmay@object-workshops.com

Problem Topic
RMEAS: What is diff of n vs. n1?

Problem Description
RMEAS/ - does ~n1~ for VECBLD override (that is, invalidate or replace) ~n~? Or is ~n~ used in addition to ~n1~? What is the difference between ~n~ and ~n1~?

References
None

Related SIRs
None

Suggested Resolution
This SIR has been referred to the SME for further research.

Support Documentation
None


Resolution

Warning!!

The following statement is only a resolution to a Standard Improvement Request (SIR) and is NOT part of the current DMIS standard, nor is it guaranteed to become part of the next revision of the DMIS standard even if voted and accepted by the DMIS National Standards Committee. This resolution is tentative because it may not be incorporated into the next version of the standard, it could be changed prior to the next release, or it could be changed as the result of the "public review and comment" period required for the next version of the standard. If you choose to use this tentative resolution, you do so at your own risk since at this time it is not part of the DMIS standard.

Resolved per 8/98 DNSC Meeting Oak Ridge, TN.
Modify the VECBLD definitions in RMEAS.

Modify the first sentence of each VECBLD definition in the RMEAS area (Pages 210,216,221,225) to the following:

"VECBLD signifies the sampling method to be used depending on the value of n1. These samples will be automatically taken by the DME to locate or locate and orient the feature prior to measuring it."

Attachments
None

Notes

Added by Mike Holloway, hkm@ornl.gov on 7/31/1998

Reference to this SIR was foundin the Gaithersburg meeting minutes on 4/10/97.

n refers to the number of points to be measured, the same as for MEAS.

n1 refers to the number of points taken automatically to locate or locate and orient the feature being measured. These points are taken in addition to the measurement points.

Added by Interpretation Sub-Committee, gph5@chrysler.com on 8/4/1998

Modify the first sentence of each VECBLD definition in the RMEAS area (Pages 210,216,221,225) to the following:

"VECBLD signifies the sampling method to be used depending on the value of n1. These samples will be automatically taken by the DME to locate or locate and orient the feature prior to measuring it."

Return to SIR List