DMIS S I R Entry

Dimensional Measuring Interface Standard
Standard Improvement Request

SIR No.
97-47
DMIS Release
3.0
SIR Type
Error
Severity
Documentation Deficiency
Status
Resolved
Date Submitted
August 12 1997
Date Validated
August 12 1997
Date In Process

Date Referred

Date Vote Pending

Date Closed
August 20 1998
Action
Clarifications
Submitted By
Thomas Kramer
NIST
Room B-124, Bldg. 220
Gaithersburg MD 20899
USA
Phone: (301)975-3518
Fax: (301)990-9688
kramer@cme.nist.gov

Problem Topic
Sect.3.1.1: Typo in code example

Problem Description
Page 12, second line: Currently reads "s4.25 Z_dim, A_10"

This appears to be intended to be an example of a DECL statement, but the line is meaningless as is. At the least, the first half of the line is missing, and a comma is missing. A line or lines may have been omitted.

References
None

Related SIRs
None

Suggested Resolution
Rewrite the line to be a valid DECL statement. If lines have been omitted, put them back in.

Support Documentation
None


Resolution

Warning!!

The following statement is only a resolution to a Standard Improvement Request (SIR) and is NOT part of the current DMIS standard, nor is it guaranteed to become part of the next revision of the DMIS standard even if voted and accepted by the DMIS National Standards Committee. This resolution is tentative because it may not be incorporated into the next version of the standard, it could be changed prior to the next release, or it could be changed as the result of the "public review and comment" period required for the next version of the standard. If you choose to use this tentative resolution, you do so at your own risk since at this time it is not part of the DMIS standard.

Resolved per 8/98 DNSC Meeting Oak Ridge, TN.
Correct example.

Change:
s4.25 Z_dim,A[10]
To:
DECL/COMMON,INTGR,Z_dim,A[10]

Attachments
None

Notes

Added by DNSC, rui@ornl.gov on 8/7/1998

DECL/COMMON,INTGR,Z_DIM,A[10]

Change Line 2 to above.